by ghubbard · 8y ago · 0 comments
> If you have a typical grid tied system (microinverters or normal string inverters, so easily 95+% of installed rooftop solar), the system is technically incapable of running off grid (without additional hardware). There's no waveform to sync with,
A residential no-break has no waveform to sync with as well.
Something capable of syncing to the grid and then more or less keeping pace even if the main grid goes down should cost very little today. (And when the grid goes back it shouldn't have drifted too much unless something ridiculously big happened)
Only running at a fraction of their max available output allow enough headroom for high peak startup draw from loads, and headroom for clouds and planes passing overhead.
Frequently cutting in and out as the load regularly exceeds available supply.
Keeping the frequency sync is the easiest problem to solve, the article even covers what would happen if you tried to use a little generator to produce a sync signal.
Most solar dealers have a one-size-fits-all product that they fit to nearly all homes without much modification. The homeowner thinks they are buying something that will save them a fortune and eliminate their need for grid power. In reality they discoverer that solar is persnickety and they will get nowhere near eliminating their grid reliance. And when you do the math you realise that it might take 10+ years to recoup the high cost of installation and by that point your batteries will need to be replaced and your solar panels will have lost some of their efficiency.
I know people who have gone fully off-grid in Ireland, but they don't just rely on solar. They supplement with wind turbines and in some case hydro power from streams.
Rooftop solar is popular because the payback period is short enough for homeowners - well under 10 years here for a system that is built to last at least 20. Modules built now degrade about 0.25% per year. Solar farms built now are typically financed as 25-30 year projects.
Source: I am a data analyst at a solar engineering firm.
As you said:
> Keeping the frequency sync is the easiest problem to solve
When the grid comes back from a blackout, chances are that it browned out beforehand so your sync is to a low frequency and coming back it'll be high frequency because the grid wants to compensate for loads jumping back on.
Additionally the components to generate your own waveform are cheap, yes, but not that cheap, adding them to the microinverter would increase cost quite a bit.
And you'd still need a transfer switch because if you happen to be 180 degrees out of phase, which CAN HAPPEN then your panel will behave like a dead short at double grid voltage. The current flow will definitely exceed the maximum tolerances and the magic smoke goes out.
You will absolutely need a transfer switch just so you don't fry all your devices the moment the grid comes back. Even then, syncing to the grid is a rather delicate maneuver since the grid will be constantly changing phase and it'll be simpler to shut down all inverters, connect back and have it all run back up on the grid itself.
It's called a line-interactive UPS. You can buy it for $200.
A line interactive UPS does not sync necessarily sync you to the grid, though the electronic will usually try to keep it in sync. It's not necessary here.
Not really, but depends on the state of the infrastructure, if it was really because of a power overload, yes, but most likely "your circuit" (which could be your street or your neighborhood) got shut off, in this case there shouldn't be much difference
Yes, a phase difference of 180 can definitely happen but I guess most electronics can survive a 1/60s (I'd say even 1/10) switching time, which is probably enough to have the grid take over.
(Or of course you could have the grid and solar charging batteries then your own high power inverter for your house but that of course would mean $$$$$$)
And you'd still have to sync the inverter, having the inverter simply continue to run until it's back in sync with the grid, then just reconnect (as a previous comment wanted) is likely not an option for most consumers.
For that it would likely be cheaper to have a full DC stage as you mentioned.
Just shut it down, flip the switch and restart. Everything else will just be prohibitively expensive because it needs to be very safe.
If you get the phase wrong then you'll either reduce the lifetime of your components or the components explode after the nearest power plant tries to pump all available power into your poor inverter.
When the two are aligned within a good-enough tolerance the system will switch back to it's regular state of mains + solar ( + batteries + wind + generator + etc / whatever).
These are all solved problems with commercial off the shelf components.
It looks to me like microinverters are a commercial off the shelf product?
Will a microinverter do all of the things a multi-component phase-syncing system with automatic transfer switches do? I don't see why a microinverter can't be built with these components integrated. I can't tell you if such a unit exists as I'm not well versed in the product range.
As far as a price comparison goes, I guess it only makes sense to compare a like-for-like system?
Manufacturers of solar hardware love to charge you an extra $1000 for that extra firmware though...