1289 points · by kwiens · 8y ago · 340 comments
Watch crystals run at 32[.768] kHz because you can divide with a binary counter by 2^16 and get 1 pps to drive the Lavet stepper driving the seconds hand.
Watch crystals are also commonly used by MCUs for their RTC (real time, very low power clock), but never used to produce the main clock of a SoC or something like that. Mostly because that'd need an insanely high multiplication through a PLL (higher frequency multiplication ~ higher phase noise). Base clock crystals are typically 20-50 MHz.
Quartz crystals used to be hermetically sealed.
Are they sealed against helium though? It can get through a lot of materials that more common gases can't.
The sealing is mostly because of humidity. I wouldn't expect quartz crytals to be overly sensitive to some gas, since they're basically tuning forks; the crystal physically vibrates in a resonance mode caused by and inducing an electric current across the crystal.
Fairly standard technique to run the watchdog off the RTC clock, because that might still work if the main clock is wonky.
I said "historically" because I don't know is if these are still important issues on a modern system relative to all of the other things that are probably using the main system clock during sleep mode, and the more generous battery.
https://www.reddit.com/r/sysadmin/comments/9si6r9/postmortem...
(https://www.reddit.com/r/sysadmin/comments/9si6r9/postmortem...)
Hydrogen would be even better of course but it is rather dangerous when mixed with air.
You can find the formulas in a typical college chemistry textbook.
They don't - even knowing He is more expensive that H, because helium is better at leak testing than hydrogen is
Repeated bouts of guessing where the leak might be and trying to plug it (usually by welding or re-machining some part), cooling down, checking if it worked, warming up, ripping some more of your hair out, repeat.
Just having fun with your typo...
Added bonus: if the metals in question form chemical bonds with hydrogen, (titanium in particular) it will happily do so, even if it's deep inside the metal. The metal will turn very brittle very quickly if it's exposed to molecular hydrogen.
After debating late nights about whether to pony up for the new better-sealed clock, someone said "Screw it, throw it in the user agreement."
The air’s usual O2 concentration is ~20.5% and it looks like safety monitors trigger at 19.5% and 18%: https://www.pureairemonitoring.com/all-categories-gas-monito...
Helium makes up less than 0.0005% of air naturally. I’m guessing that increasing He concentration 1000 times to 0.5%, for example, is enough to cause problems for iPhones, but not enough to trigger the alarm or pose any danger to people.
That's why it seems like oxygen concentration monitors are a good idea for hospitals with liquid He. They don't really need to monitor helium levels since that's not the direct cause of problems. It's only an issue (but a big issue) if there's so much He released that it displaces enough air to meaningfully dilute O2 concentrations.
The author's cavalier "I bet the nurse’s voices were higher pitched that day!" was incredibly inappropriate given the potential danger.
The article I linked mentioned that O2 monitors are legally required for hospitals in NYC. That regulation might have been created because in 2000 someone working on an MRI machine died from a Nitrogen leak (it's also used for cooling and like He, the only risk is that it displaces O2). It's likely this person wouldn't have died if an O2 monitor was in place that sounded an alarm fast enough for the victims to leave the area. http://www.nydailynews.com/archives/news/nitrogen-gas-leak-k...
edit: googling a bit more found some interesting references on dealing with "oxygen-displacing gases". O2 monitors are on the long list recommendations/requirements. One thing I found interesting is that at one laboratory part initial assessment involves a controlled release of the maximum amount of gas that will be stored and then measuring the drop in O2.
https://www.ors.od.nih.gov/sr/dohs/Documents/ProtocolOxygenM...
http://www-group.slac.stanford.edu/esh/eshmanual/references/...
Hospitals of reasonable size typically have an on-site clinical engineering team that handles those kinds of situations. Important (that is, capital expense category) hospital equipment will typically emit all kinds of warnings and alarms way before anything's actually a problem, because everyone would rather rely on the on-site engineering spending a little extra time silencing false positives then leave anything to chance.
"So, i noticed some of the workers' iwatch's weren't registering the users' heart-rates. At first, I thought it was because they had all died from suffocation from the massive gas leak. But, then I discovered something interesting... it was actually the helium molecules worming their way into the internal clock chip! Amazing day."
Nobody could adequately explain to those of us in the CS dept why we had to take 3 semesters of Chemistry. Bits of it hung on and from other sources such as space exploration articles I recall this much:
Fires and lungs both operate on partial pressure of oxygen. As long as nothing else in the air is toxic, your body cares that it gets X oxygen molecules per cubic centimeter of air in your lungs, not Y parts per million. Those deep sea submariners are breathing mostly helium with a small fraction of oxygen in it. If you just compressed surface air there would be so much oxygen that your hair would explode when you ran your hand through it. Assuming the electronics didn't burst into flames first. And if you didn't set yourself on fire, that much nitrogen would kill you pretty quick.
So the question is, does helium displace air or mix in with it? I believe the answer is 'some of both'. If that's the case (and I think we can infer that from "the alarms didn't go off") then a good amount of helium might reduce the oxygen partial pressure less than going to 3000 feet above sea level. So what's the Venn diagram of COPD sufferers, in a hospital wing near the MRI machine, that aren't currently on supplemental oxygen?
In addition, unlike carbon monoxide, helium doesn't bind to, well, anything and certainly not hemoglobin, so it doesn't present a momentary exposure hazard either.
Ideally you would pressure test and purge new work with nitrogen as well in order to prevent a potentially combustible mixture from forming inside the pipe while the air is being purged from it.
As to the safety of purging natural gas directly indoors, obviously that carries some risk but it's not as dangerous as you might assume. Below a certain concentration (5% by volume) natural gas mixed with air actually won't burn freely. Also above 15% natural gas by volume won't burn freely. The risk of an explosion is only present in that 10% range. If you're putting in a new gas stove in your kitchen and you crack open the valve with the hose off of the stove until you smell gas, that's not a ton of natural gas that you've let out into a room with a relatively huge volume. The pressure of a natural gas pipe in a house is actually very low, only around 0.25 psi. It's coming out slow enough that you've got plenty of time to turn off the gas before you come anywhere close to hitting that lower explosion limit where things get extremely dangerous.
I discovered that the helium leakage occurred while the new magnet was being ramped. Approximately 120 liters of liquid He were vented over the course of 5 hours. There was a vent in place that was functioning, but there must have been a leak. The MRI room is not on an isolated HVAC loop, so it shares air with most or all of the facility. We do not know how much of the 120 liters ended up going outdoors and how much ended up inside.
I've seen multiple vents of ~1500l of liquid helium (~1,050,000l of gaseous) in a single day from a couple bad MRI units when I worked at a company that makes them
Only "dangerous" place to be was in the fragmentation path of the burst disc (which was enclosed in the top of the unit (at the time)), or directly in the path of the nearly-liquid (ie extremely cold) helium as it vented
It dissipates extremely rapidly
But there are plenty of things to help you out here. First is that helium is very light. So if you pass out and fall down you will be in a lower concentration of helium (assuming you are not in a sealed room). (Labs with heavy gases have vents on the floor) If the room is reasonable ventilated you should be fine. It dissipates fairly quickly. Helium permeates through most things, but this is a slow process so probably won't save you.
If you displace 30% of the atmosphere with helium, the O2 concentration drops from 21% to 15%. That's low enough that you'll probably start to see mild cognitive impairment, but it's still plenty capable of supporting life. However, a 30/70 mixture of helium and air is about 67% as dense as normal air, which means voices would be pitched more than half an octave higher.
Sadly my immediate reaction to this post on /r/sysadmin was to discount it, or rather attribute it to some external factor that nobody could possibly figure out and entirely unrelated to the MRI. In this case I was quite happy to be proven wrong by the follow up posts and subsequent article.
I'm really curious why something they can generalize to "helium leaking into the quartz oscillator" only affected Apple products. What feat of manufacturing keeps a broad range of OEMs safe on the Android side but so eludes Apple? Worse yet, was some "cost savings" engineered between iphone 5s and 6 that ultimately introduced this issue?
The other phones involved still used quartz.
"But quartz oscillators have some problems. They don’t keep time as well at high (and low) temperatures, and they’re a relatively large component—1×3 mm or so. In their quest for smaller and smaller hardware, Apple has recently started using MEMS timing oscillators from a specialized company called SiTime to replace quartz components.
Specifically, they’re using the SiT512, 'the world’s smallest, lowest power 32 kHz oscillator.' "
So it was size, not cost that led Apple to be using a susceptible component.
Every time my colleague brought his phone to the control room the Cellular stops working for like a day or two, but my 6s worked just fine anywhere even next to a Dewar that's venting Helium. Now the mystery is solved!
BTW, among us there are others who accidentally brought their phones near or even into the MR bore during maintenance, but none of these devices has done any permanent damage to our phones, except one accelerometer on a cheap Chinese phone, even in a 7T magnet. So I never thought that MRI could be causing the problem.
That said - a 120l leak of liquid helium is both stupidly expensive, and highly damaging to the MRI unit: there's a bath of ~1000-1500l of liquid helium in an MRI to keep the superconducting coils at superconducting temperatures. Losing ~10% of that volume probably means the unit won't work
Nope - well, not with any of the ones with which I am familiar: they're shipped full most of the time
Also, this could be a potentially catastrophic tool for terrorists. As trivial as it sounds, it's even worse than a traditional frequency jammer because it renders the device unusable instead of just not being able to communicate with the outside world.
Edit: On the other hand, interesting counter-terrorism tool as well. Is there any precedent for the CIA using this sort thing intentionally?
Liquid helium is rather expensive and would likely draw attention in areas where it's not usually handled. Really doesn't sound like a useful terrorism tool.
I think the infamous Thunderf00t does a decent job of explaning why https://www.youtube.com/watch?v=l6uLUaqgWY0
One of our multi-practice facilities is having a new MRI installed and apparently something went wrong when testing the new machine.
[...]
I discovered that the helium leakage occurred while the new magnet was being ramped. Approximately 120 liters of liquid He were vented over the course of 5 hours. There was a vent in place that was functioning, but there must have been a leak. The MRI room is not on an isolated HVAC loop, so it shares air with most or all of the facility. We do not know how much of the 120 liters ended up going outdoors and how much ended up inside.
Say I scored a big truckload of helium, 5000 l. (The contents of my tank will expand to 3750 m3 of He gas.) Then I got access to a ventilation duct into the subway. I manage to hook up my tank and start depleting into the subway. Assuming 20 m2 cross-section for a tunnel: if I could do the emptying at once, I could fill 0.187 km of tunnel completely with He; killing all vermin in that section.
But hey my goal is not to suffocate (that would be boring, right?) but to fritz electronics. So I do it slow and steady into a station. Say I want to keep the concentration of He in the station at around 0.1%. (I assume it would take time for operators to detect this. I don't know how sophisticated gas detection is in subways.) Let's assume an airflow of 5 m3/s into that station. I'd need 0.005 m3/s He or 400 m3 per day to keep the level at 0.1%. So for only one day, I'd need to get around 500 l liquid helium into position.
There are easier pranks to play.
Or if you are some kind of compressed gas terrorist, 5000L of compressed oxygen or acetylene will do a lot more damage than helium.
Anyone who can mount a helium attack can mount much more severe attacks.
I think the probability of some eccentric and well-supplied terrorists trying to ruin Apple devices with helium is so remote as to not be worthy of consideration.
Even if it does come to pass. Oh well, I'll buy another iphone, or an android.
It is, but only in the same sense that a van in the wrong hands could be potentially catastrophic.
A bit of googling on MEMS RTC revealed this slightly dated article which I thought was still interesting: https://www.maximintegrated.com/en/app-notes/index.mvp/id/55...
Turns out one of the main reasons to switch is for the smaller packaging vs quartz oscillators.
https://www.eevblog.com/forum/chat/helium-in-the-air-kills-i...
But an electromagnetic pulse would have taken out medical equipment in the facility as well, and they were working fine!
I suspect medical equipment is designed to a higher standard of EMP resistance than most other products, especially equipment designed to sustain life. Phones also have antennae specifically designed to pick up EM fields, while medical equipment like an EEG or ECG is specifically designed to reject them.
Likewise, the devices "reviving" after a week is not unusual if they're just resetting due to power loss. Immediately disconnecting and reconnecting the battery would for sure differentiate between helium (device remains dead even after reset) and EMP (device reboots successfully.)
They must have some seal in place and fortunately our air is Nitrogen, O2, and a little bit of Argon. These can’t get through the seal! Helium is only found in minuscule amounts naturally and apparently this concentration is so low it doesn’t matter.
Helium is special because is it has the smallest kinetic diameter of all the noble gases. You can compare its diameter to other gases here: https://en.wikipedia.org/wiki/Kinetic_diameter#List_of_diame...
Helium is frequently used in leak tests since it has a way of working through even the tiniest of leaks. Elemental Hydrogen is of course smaller, but I believe you only find Hydrogen as H2 which is a larger molecule than Helium.
Does that mean that water (in some form) also acts like helium and would be able to get through that seal?
While water’s overall charge is neutral, its charge isn’t distributed symmetrically ans tbis makes it a rather polar molecule. This means part of molecule have different charges which leads to attraction to other water molecules thanks to van der waals forces. Basically water naturally clumps up and won’t squeeze through tiny holes even if it’s kinetic diameter would technically allow it. (Though I believe very high pressure can force it through)
Water’s polarity is what causes surface tension and droplets! For comparison, gasoline is relatively nonpolar, though not as nonpolar as He. If you’ve ever spilled some you can see it spread out immediately and avoid the droplet formation and cohesion you’d see with water. Similarly, water tight containers might not be gasoline tight. (but don’t test this out...)
To correct my comment from earlier: Helium is special because of its small kinetic diameter AND because it’s naturally found in a monoatomic and nonpolar form, as are all noble gases. This lack of polarity leads to minimal intermolecular attraction that would cause clumping and limit flow.
(I found a reference that helium can be measured flowing through a 1.0nm hole, albeit at a very low rate. I wonder how close to the 0.260nm kinetic diameter a hole can get for He to still flow)
It's really hard to contain helium. It'll leak through pretty much any solid material.
That is exactly the case. From the article, helium (and to a lesser degree, hydrogen) have very very small molecules and are able to slip past very small imperfections in hermetic seals.
Not sure how you would get it going again and / or how necessary that would be. Perhaps heating it to excite the helium trapped in the oscillator and hoping it bounces out.
Could end up being a pretty easy go to law enforcement trick. Put a phone and a helium balloon in a ziplock bag, pop the balloon, pause the phone, deal with it later
the math seems couple orders off - the 120l would make less than 900m3. The 90000m3 would be on the scale of the total volume of a multi-story hospital building.
120 × 750 = 90000 liters, or 90 m^3. Very annoying.
First, it illustrates an MRI story with a (mislabeled) picture of a CT scanner.
Then, it overestimates the volume of gas expelled by a factor of 1000.
170L X 750 = 90k L = 90m^3.
This would fill a 35m^2 (about 350 sq ft) room, maybe the size of a living room, with pure helium.
http://www.airproducts.com/Products/Gases/gas-facts/conversi...
But if you're going to criticize their math, you might want to double check your own math.
90 m^3 = 2m (height) x 6.7 m^2
(ok, 2m is a little low, 2.5m would be more comfortable.)
But, I'm not sure your math is quite on the money either.
I'm and Android user so I have no skin the the game. I'll have to talk to some people at work tomorrow. A few guys are iPhone users and work in direct proximity to the helium leak testing stations or use them as well. I know a woman in the office didn't like her iPhone because of numerous problems but I never thought to press her for details.
I... don't think that's a thing that MRI machines can do. They're even shielded!
Technically, watchOS is iOS
Exposing iPhone to environments having high concentrations of industrial chemicals, including near evaporating liquified gasses such as helium, may damage or impair iPhone functionality.
Apple Devices are Helium Detection Canaries.
Here's the Zeppelin NT cockpit, but I can't tell what kind of gyros they may be using: https://upload.wikimedia.org/wikipedia/commons/3/33/2003-07-...
Did they add anything to it, the write up was quite comprehensive. I’ve got a bad feeling about this.
I guess they're fine under normal conditions because typical atmospheric molecules are actually too big to get inside? I'm not clear why the particular clock that Apple used is susceptible but other ones aren't. I guess they're sealed better.
The article is pretty straightforward and engaging; it's worth a read!
You probably didn't mean "helium molecule"–or if it was, that would very odd, as helium as a molecule is very rare…
He2 is rare enough that the few times I've heard it spoken about, people have usually said "helium dimer" to make it clear that's what they mean. Since that's the rare case, it's the logical one to be explicit about.
I have also seen this, but it has normally been almost exclusively confined to when people talk about the "particles" of gas from a kinetic theory point of view.
Molecular helium happens to be identical with atomic helium, where an atom is the smallest unit of an element (not a chemical substance).
Water (H20) is a substance whose smallest unit is a molecule of 1 oxygen + 2 hydrogen atoms. Helium is a substance who's smallest unit is 1 helium atom.
> A molecule is an electrically neutral group of two or more atoms held together by chemical bonds.
> In the kinetic theory of gases, the term molecule is often used for any gaseous particle regardless of its composition. According to this definition, noble gas atoms are considered molecules as they are monatomic molecules.[9]
Do you think anyone's understanding was negatively impacted by the use of the word 'molecule' here?
What I don't get is how these helium molecules diffuse into the iPhones so easily, an awful lot of helium must have to leak for that. Normally helium - balloon sized quantities - tends to prefer going skyward rather than hide in an iPhone.
But since that seems to not be the case it would be good to turn up at a concert where everyone is playing with their hand rectangles rather than enjoying the moment, then to release some helium to fix that for them...
Yeah, well maybe they don't tell you all the details and special cases in school...
"There is some empirical and theoretical evidence for a few metastable helium compounds which may exist at very low temperatures or extreme pressures. The stable cation HeH+ was reported in 1925."
Maybe you do get these things happening inside a particularly pedantic iphone but regular chemistry suffices here, the general idea of the Periodic Table stands true, noble gasses on the right hand side don't react to instantly form co-valent bonds with the other elements. Sure, anything can happen in the side of a giant thermo-nuclear reactor but, in every day situations classical understanding works great.
This is a long way off the article, you are having a laugh!