210 points · by zdw · 2y ago · 76 comments
> Google translation: When switching on from a standing start, a noise can be heard that is reminiscent of playing through a scale on a tenor saxophone. It is created in the three-phase motors by controlling the power converters. The noise is twice the clock frequency of the pulse inverters, which is gradually increased. The frequency changes in whole and semitone steps over two octaves from d to d" in the tone pool of the root tones. It is a Dorian scale on the root D. Theoretically, it would be possible to program the locomotive in such a way that it emits completely different sounds. However, the manufacturer has opted for a scale because these sounds are perceived as pleasant by the human ear. This makes it possible for a four-voice tone to result when the wheelsets are spinning (for example due to wet rails).
No wonder the Austrians (who have a reputation of being music lovers) have most of these engines...
https://en.wikipedia.org/wiki/Insulated-gate_bipolar_transis...
Are they manufactured using regular silicon lithography? You'd think when making something so large you could just mix up the chemicals instead.
(silicon lithography is more of a broad range of processes: digital vs analog vs power vs MEMS all have very different needs, and so a process designed for one will look very different to another, and one designed to allow multiple will be making compromises)
Here's a data sheet for a somewhat larger one.[1] The control signal is only 6 volts at 5 mA. It's incredible that this is physically possible.
[1] https://www.infineon.com/dgdl/Infineon-FZ1500R45KL3_B5-DataS...
I was in Austria last year, and a bunch of the trains starting from a standstill had a "gradual acceleration" algorithm for their traction motors. As the drive frequency increased, you could hear the drive motor whine (or maybe it was the inverter?) along with the frequency. It was fascinating, because it played chords as it accelerated: root, 2nd minor, 4th major, 6th minor, octave, then it would pause at the octave and do it again after a few seconds until it reached max power I assume. Each chord had a very faint tritone added to it relative to the chord tonic, so you got this really harmonic pulsing.
After the second course there was too much rail noise to hear what happened, but it was fascinating. I'll try to find a video, I know I recorded it.
Power in Austria/Germany is delivered to trains via a really weird standard too: something like 25hz 27 kV. Leftover standard from 100 years ago.
But it can be configured to play other tunes. Here is a rare recording of it playing the Austrian anthem: https://www.youtube.com/watch?v=UkdQmDGU9AM (another recording: https://www.facebook.com/unsereOEBB/videos/290883783832057/)
Just compared it to a midi player... first video starts on a G. It may not be equal temperament? Some of the scale degrees sound just slightly flat or sharp.
The German standard you are thinking of is 15kv 16.7Hz.
https://youtu.be/IRJIJPTUXXE?t=474
A drone ?
The camera follows the train so precisely that it seems it is mounted on the train, but it passes on the other side of some objects so it cannot be mounted on it.
If you want an incredibly detailed 3 hour history of the genre: https://www.youtube.com/watch?v=5vwE_p9SCXw
Like Microsoft Flight Simulator, but for trains.
Example: https://www.trainsimworld.com/
An easier giveaway might be the floating teal icons on the station platform.
VFD AC motors will intrinsically self-correct for overspeed when static traction slips and starts going into dynamic region (due to the frequency being slower than the slip/overspeed) and re-enter static friction region. DC or ICE will react to the lack of traction by turning faster as you hit the dynamic friction region and "spin out". Traction control is always reactive and lags behind. Last I read the difference in traction on rail for AC vs DC was on the order of 50%(!).
It's also why EV cars have stupidly awesome traction in adverse conditions under acceleration, trains had been perfecting that technology for decades.
That also makes fully electrifying these things less off a technical challenge and more of a battery cost challenge. Mostly size and battery density isn't that big of a deal even. There's plenty of room in a large heavy vehicle to put some batteries. Even if they weigh a few tons it's not necessarily that big of a deal. Except of course if you need to go half way across the globe with a ship. But shorter range of up to 100-200 nautical miles if very doable now. A big mining truck has plenty of space and they are big and heavy anyway.
(/s, just in case; ye olde 20 tonne 1980s buses were extremely noisy, and it was not great.)
To me, the example of the PWM wave [1] looks like the VFD mode, but:
- instead of varying between [-V..V], varying between [0..V]
- instead of having a regular variation of pulse pattern to get a regular wave, having an irregular pattern.
But that irregular pattern (or non-recurring pattern) only seems to be an illustrative example to match the brown wave shape, and I assume you wouldn't want to have irregular wave patterns to drive your engine?
Btw nothing beats the sounds made by both steam- and opposing-piston diesel engines - you can feel the power. Sounds made by electric engines are mostly whining.