264 points · by speckx · 1mo ago · 280 comments
Plug-in solar is suboptimal in many ways, but it does sidestep a lot of those hurdles. Not too surprised to see it on the rise.
Another thing that might be worth keeping in mind is that plug-in solar panels are often installed vertically - i.e. balcony solar. In which case the peak of the panel's generation is offset to the edge of the typical "duck curve". If it gets popular enough to affect the grid, it might get the solar-induced demand slump larger, but make the edges even sharper.
Would that make grid scale battery storage with its instant response even more important?
For the price you’re talking about, you could also get a system with 15 kW of panels with a good 20-30 kWh of battery storage too!
It's the regulation cost that's really hurting us.
Just the required paperwork for the permit in my region cost ~2.5k. structural engineer was 800, architecture diagram was 800, certified electrician stamp on the plans was 800.
Add in the extra cost to facilitate RSD (~5k after mlpe devices, and extra wiring) and tack on the cost for utility interconnection agreements.
Then deal with the NEC requiring UL listed items with no/very little cross certification with things like CE which effectively means you can't buy equipment from China, at least not without a US shop taking a huge markup for branding/certs.
---
Overall, it's just a mess. I walked away from the project (completed, all approved) with a huge dose of skepticism for the permitting/certification/approval process.
11.2kw in panels, ~12kwh lfp battery, split phase 240v install - ~28k usd.
Of which ~10k was regulation driven, and doesn't change much by install size.
No need for permits for rooftop solar and the only dealings I had with the energy company was filling out an online form to register it. Took maybe 2 minutes.
I did not add a battery because at the time it would have doubled the price. Also, because I have net metering the battery never pays itself off.
(My installer ended up flaking on me, and then I gave up because NEM 3.0 was coming too soon to find a fallback.)
At least you bought them 8 years ago and not 20, you could have had a 1.5kW system for the same price.
Homeowners are getting the short end, but the solar installers are doing well.
That’s the total cost including all materials and labour from scratch to a fully functioning system.
Matt Ferrell just did a video on this recently https://www.youtube.com/watch?v=R3eEzdpi12I
This setup would cost north of $50k (possibly north of $75k, depending) if installed by contractors. Labor costs are extremely high here, since COL is extremely high.
> I'm in Europe
Wait until you hear about American Insulin.
I do wonder if having an electrician come by after the fact to inspect it counts as "supervising", though.
Free refills on soft drinks are generally still a thing in the U.S.
I got 7.6kW fully installed with inverter for $8k CAD a few years ago.
You mean "to have installed".
I installed 6.7kW for $12k, but did all the work myself (with a permit).
$30k is mad.
Permitting was new for me and it was tough to navigate alone, but definitely possible.
If you don't have utility approval to connect, you won't get net metering benefits, although you could offset active use (and if you had battery storage, I guess you could make it work). At least my meter doesn't run backwards, it has a count for energy in and a count for energy out. If we didn't have utility approval and had significant energy out, I'm guessing there would be questions. We have a fairly generous tarrif, and our system doesn't make sense without utility approval --- we generate on one meter and use on another meter and rely on meter aggrigation for the generation and use to offset, and they will offset 1 for 1, once the account gets fully set up.
At that date I got into the feed-in-tariff scheme, and it has long since paid for itself just in cheques mailed to me by the utility.
Also, with the price of solar panels decreasing below most (wood?) building materials with way higher durability, no paint required, why wouldn't it replace most sun facing siding applications aside from being "ugly".
The plug in solar systems are small and usually mounted in ways that don’t capture as much energy as the same panels mounted on a roof. These systems aren’t going to get popular enough to make a big difference in anything.
I think it’s nice that they’re available for people to do some small scale offsets, but I think they’re more of a gateway to better solar installations. They also send people down the path of investigating battery storage add-ons, which might actually be a better long term solution for everyone.
If we can get to a point where we can buy plug-in batteries that are subsidized by requiring coordination with the grid, the power companies could get distributed, controlled battery storage to work with their demand curves. This can already happen with the bigger permanent install batteries.
They already are in a few countries.
The inverters follow the grid AC and shut off their output if they are disconnected or unplugged, so the plug is never "hot". The power they input into your home wiring/the power grid is limited to 800 Watts as to not overload any installation. And the power meters know not to run backwards if you happen to feed power into the grid. Most can even meter how much power you fed in total (you're not going to get paid for it, though)
If you want, you can add battery storage that follows the same rules but lets you save excess power during the day to feed into your home at night or during demand spikes (washing machine, ...).
The setups are dirt cheap (often 200 - 300 EUR for an inverter and 800 - 1000 W(peak) of solar panels) and pay for themselves in about 1-3 years in saved electricity costs.
i.e You have a circuit with max current 16A; clever end-user plugs in 3 x 800W panels into different sockets BUT they are unfortunately on the same circuit; now 26A can be potentially drawn through a single cable IN THE WALL without tripping the breaker. This is a BIG fire hazard.
And you can't wave this away with instructions. It has to be 100% impossible for an end-user to do this.
Of course your argument still stands, but we're talking about at most 3.5 A extra current, not 10 A. Home installations seem to be adequately sized to be able to handle that load. At least I'm not aware of any reported incidents, and people have been putting them up for quite a few years already. And typically, German regulations err on the side of caution.
But sure, with 110 V, you will have more problems with the extra current for the same power, so in the American grid there could be further precautions necessary.
> you can't wave this away with instructions
But apparently you can with legislation about instructions.
Edit: government safety investigation https://assets.publishing.service.gov.uk/media/6a32bfea0bea2...
Final edit: "61% of respondents support having one device per household circuit while 19% considered that only a single plug-in solar device should be permitted per premises citing alignment with 44 Engineering Recommendations G98 Issue 2 Amendment 1, impact on the network, old wiring in properties and the ability of consumers to correctly identify separate electrical circuits.
Government response: Having considered consultation responses and stakeholder feedback, the government's approach is to limit the deployment to one per power circuit, subject to corresponding changes to the G98. Some respondents suggested limiting the total capacity per dwelling to 800VA, but we think the evidence for doing this is weak considering most UK dwellings have a minimum of two power circuits"
-- i.e. they thought about it and the concerns got outvoted.
It's probably fine. There's a lot worse lurking in outdated UK installations. Then we get on to ring circuits, which the rest of the world disagrees with and also seem to be fine.
In the US, even with a warning, you'd get regular home fires as people hooked one of these panels into every available outlet just because they can. I wish I were joking.
I hope it's at least "probably fine". I've seen some pretty shoddy electrical work in my lifetime (including new installs) and am now of the mind that the deep-defense-in-depth of electrical safety we have these days is to also "cope" with shitty electrician work.
Seems like the worst case scenario is when you mix solar panels with load on the same circuit.
800W at 110v is about 7 amps. Suppose you have a 7 amp solar inverter plugged in as the first thing on that circuit. Further down the line, you have 22 amps worth of load. The circuit breaker sees 15 amps, but the wiring between the panel and the load is carrying 22 amps, which would ordinarily trip the breaker but it doesn't because the solar setup is masking it.
I'm not an electrician. Perhaps wiring code has enough safety margin that being 800 watts over on some circuit isn't actually a serious safety concern, but I could understand why this might not be allowed.
The EU is on 230v, so maybe it's a bit more practical over there because you can add twice the solar capacity for the same amount of additional current you'd have in the US, so they aren't eating into the safety margin quite as much. Though it seems they also use thinner wire gauge generally, so maybe the difference is moot.
Don't get me wrong, I think they're a spectacular idea, especially for renters. But you'd need an electrician to check the circuit and maybe even have a special balcony-solar-plug to prevent people plugging in too many panels in the wrong locations.
Quick edit: Random idea. I guess if the panel could communicate with the RCBO it's connected to and that RCBO can dynamically alter it's trip current could also solve it. But again, that's an electrician call and new thing installed.
I passed high school physics with good grades, so … I’m not surprised other people instinctively say this can’t possibly be a good idea.
But it’s AC, the electrons are shuffling in both directions at 50/60hz
Voltage goes forwards and backwards and odd but current also goes forwards and backwards, for both appliances and generators.
The difference between consumer and producer is only the phase angle between the voltage and current waveform.
Because power is VxA, do that across the wave cycle and the power direction changes for consumers and producers.
At every junction, Kirchhoff’s current law will sum the currents so you get a “net current” waveform on a wire that might have both a kettle and a plug in solar panel.
That summation means the kettle will chomp as much current as the panel can deliver and than take more from the grid. Swap the kettle for a small LED which takes a fraction of the current and the sum gives a NET supply, and on to the next junction.
It took me a while to get my head round it too.
Current load pulls the voltage down, sourcing current pushes it up. No bother, as long as your sources cut out if the voltage goes too high, and your loads cut out if it goes too low.
In terms of electricity and physics, this is unremarkable, the bit that probably scares people is the fact that you have a plug connected to something that's _outputting_ AC, particularly for those of us with 240V supplies.
If it were any old AC source on the other end they'd be correct, but current technology allows the output to be cut in milliseconds, faster than the period of a single AC wave, once the plug is removed.
Tangentially; if you have solar (mine's roof-mounted) don't assume that flipping the breaker means there's no power; I live in a 1930s UK home with all sorts of interesting wiring and flipped the breaker to change a plug socket, only to be shocked; literally and figuratively when it was hot.
When we had our solar installed, we had to make sure we had a newer power meter that could handle power both ways, so it probably is a problem for some situations, but the power flow for a single solar panel into a plug isn't enough to trip this, or maybe newer power meters are better?
We definitely think of it as somewhere a power comes out of, but I don't think it's the name, just that it's only ever been that way.
Clearly some people think of it differently if they're plugging generators into wall sockets to power the whole house, dumb as that may be.
What's new is cheap and ubiquitous micro-inverters. Before it wasn't worth putting a $800 inverter on a small 2-panel 600 or 800 installation. Now with micro inverters being so cheap, this tech becomes viable. And with loads so limited (less than a microwave) the regulation is equally light to allow this convenient plug-in solution.
On an AC circuit, all connections are duplex.
It needs to be paired with a transfer switch or it will backfeed.
Unfortunately it is a far too common thing for people to rig these things up themselves leading to all sorts of funny complications.
If you want to get an overview of the ecosystem, googling "Balkonkraftwerk" gives you the most relevant results.
I think this will be your biggest practical issue in newer US construction. Arc fault circuit interrupters are now code for any wiring in living spaces. They can be quite sensitive to weird switching loads (and sources). I was forced to swap an AFCI for a normal breaker in my last home. The power supply in my workstation triggered the detection heuristic in the AFCI about once a day. I could cause an outage on demand by running certain workloads.
Obviously the inverters and pairing technology exist, but I don't know where to buy one retail.
welcome to the future
There is also the problem of backfeeding, but this is more theoretical - even if you know to limit your power use, your neighbors won't and so your generator will trip its own breaker. Linemen are taught to either treat power lines like they are live, or to short them to ground - it can happen they don't do this and you kill a linemen, but still not as big a worry as it is made out.
They make generator "inlets" that sidestep all these problems when used correctly. Most common I've seen is a block so you can't have the inlet and the main breaker both on at once.
it is not theoretical from the POV of power company employees working on their lines. the power goes out, they go to fix the equipment or wiring, and if the inverters connected to the grid have not shutdown, there could be 10s of kW to even MWs being backfed into the system they are working on.
that's why in the US at least, grid-tied inverters are required to have protection against this. if they do not see power from the grid, they shutdown (and rather quickly).
I realize this is a complete noob question but I'm still curious: with enough "backfeeders" could it not in theory be possible that the backeeders see each other's output and keep operating?
Say, a few houses at the end of the line, each with very little electricity consumption (no-one's at home), but with panels and inverters going full tilt, something like that?
Also, people have been back peeking the grid from their home generators for decades by now. Solar and inverters are a different variation of that attack, but it is nothing new. Any utility will have procedures because they can't guarantee that's not happening and we learned years ago.
I'm not saying it never happens, only that correct procedure already makes it not an issue
If this weren't done, there would be risk of electricution to anyone working on wiring in the house or on the utility distribution network.
Skip to about 10 minutes into this video: https://practical.engineering/blog/2022/12/5/what-is-a-black...
Furthermore, the danger of backfeeding is if you do it in a power outage and you start to power your neighbors' houses. It'll overload your generator and create a hazardous situation for anyone working on the wires. (This is why you're supposed to install either a generator switch or interlock. I have one that only allows me to energize when my main breaker is turned off.)
It outputs at the same phase and frequency as the grid, and with a slightly higher voltage (think of a ball rolling down a slope from a higher voltage to lower voltage).
If the grid is down then it stops the inverter for a minimum safety period (some minutes iirc)
Solar inverters (esp for this use, but also in general) are grid following; they'll use the existing frequency and support it, and if the grid goes off they'll go off too and do no power-off backfeeding.
The inverters are thus broadly safer to be plugged in to systems that are otherwise unprepared.
Generators could be made grid-following (many are now inverter-based), but for most users that would be silly, since the supplemental power would be more expensive (and louder!) than from the grid.
It can be quite safe to plug a generator into an outlet if you take precautions to properly island the system. I had an interlock on my breaker panel that would let me turn on a 50A backfeed breaker if my main breaker was switched off.
tl;dr Plug-in solar inverters must power off within a second if they stop detecting the grid's sine wave.
Generators have no such protection and will happily backfeed through the transformer outside your house to energize power lines. Line workers are careful, but there have been deaths. After hurricanes seems the most common based on a quick search.
So it's not a stupid question, indeed you should never plug a generator into an outlet. The double-ended "suicide cord" which allows you to do that has that name for a reason. (It can be fine to plug a generator into an inlet circuit, if the electrical panel has a proper interlock that physically forces disconnect from the utility before connecting the generator inlet.)
The better way (and legal way) to do this is to have a generator plug plug installed, this way when you switch over to generator your property is disconnected from the grid.
The power from the plug-in outlet is consumed by any devices connected on the same circuit first. Any extra flow through the electric panel’s bar connecting the circuits on the same 120V phase, where the devices on them use the extra next. Any excessive power flows back out of the meter on the 120V phase line on your service connection to the transformer at the street block. The transformer might feed it to your neighbors. In any case the transformer feed electricity to the other 120V phase line back into your service connection, the meter, the panel, the other split phase bar, the circuits on it, and the outlets on them. The devices on the other split phase circuits technically are not using the plug-in power directly.
Most modern meters measure electricity going in and out on both split phase lines as a whole, as a net amount, so the electricity consumed in the other split phase circuits is offset by the plug-in power. However some old meters add the outgoing electricity up as consumption so you are paying for the electricity fed into the grid. Call your utility company to make sure.
Also, unless you have a net metering agreement with your utility company, you won’t get paid for any excessive electricity fed back into the grid.
One constraint on these I've read is that if you have sources and sinks on the same circuit, you might overload the line without tripping the breaker at the box. If I'm understanding this correctly this has caused them to limit the power of plug-in solar to a fraction of what a single circuit could potentially carry.
While the power doesn't go out often, it is a big deal when it happens and so a backup is useful. I'm still fixing the damage from the last one - the sump pumps not running for an hour in a rain storm is expensive. Fortunately it wasn't a long outage, much longer and the fridge/freezer would be a problem. In cold weather the furnace is important to keep running. There are other essential things as well that my house cannot survive without. Beyond that I want my computers to keep running if possible.
My electricity supplier sends me a message nearly every week saying if I use less electricity during peak demand times then I get free power at weekends. https://octopus.energy/saving-sessions/
Decentral battery units in substations, similar to what Tesla did in Australia many years ago. They can absorb or provide reactive power as well.
And on an unrelated note, it seems that hybrid power plants are becoming a talking point now and they seem to make a lot of sense. Like covering dams with solar panels saves on water, make PVs cooler/work more efficiently and you don’t need to worry about permits/building more grid connections because you can simply slow down hydro during daytime (and get along with grid following inverters just fine).
The breakers do not prevent power flowing from an outlet back into the panel bus. They are thermal magnetic trip devices (99% of the time). The thermal is just a strip that when you get too much current for too long gets hot, expands, and trips the switch.
The magnetic part is a coil and too much current too quickly pulls it like a lever.
Nothing here will prevent “backflow” of electricity. It can’t because AC is always going both directions. It is reversing direction 50-60 times a second
The only thing you will hit is whether the power is on the same phase as your fridge. If not it’s going back to the grid.
well old NA circuits are notoriously shittier and lower-amp-rated than in europe lol
i don't think it's a good argument against balcony solar but neither is that a good rebuttal
Don't call the US system "shittier". It is different, but that doesn't mean better or worse. Anytime the US needs more a little more power we put in 20 amp circuits for the same wattage. Anytime we need a lot more power we put in 240 volt circuits. Different, but it works just fine.
And it's the way it should always have been.
Sure, there are concerns with possibly melting house wiring, but they require some vanishingly unlikely situations to occur.
In other words, it can be useful even if it's not the most efficient way to do it. It only has to be more efficient than the status quo.
I don't have thd capital to build utility-scale solar. I do have the capital to install residential solar. My electricity is now cheaper.
I am thinking along the line of:
- You can just do it / upgrade it etc
- Robust against central failures for various reasons
- Resistant to those in charge of centralized infrastructure abusing their monopolyIf you are going through all of that, there is not much benefit to plug-in solar instead of traditional.
So when the power goes out you unplug your fridge from the wall and plug it into the battery. In essence it operates like the standard camping battery/"solar generator", a la Jackery et al.
For example Duke is for profit here in Florida, and charges about 25% more per KWH than OUC that is a public utility.
This leads to pricing where on one street your power bill is $250, but one street over its $200, often coming from the exact same power plant.
FPL is also for profit, and is cheaper than OUC.
1st 1000kwh with FPL are $0.11461/kwh Above that is $0.13461/kwh with a base customer charge of $10.52
1st 1000kwh with OUC are $0.1155/kwh Above that is $0.1405 with a base customer charge of $18.50/mo
Total cost with FPL for 1000kwh for the month before state and local tax is $125.13
With OUC it would be $134.
https://www.ouc.com/wp-content/uploads/2025/09/2025_10-OUC-E...
https://www.fpl.com/content/dam/fplgp/us/en/rates/pdf/reside...
The biggest factor Id say is FPL has significant amounts of solar and nuclear generation.
https://www.fpl.com/content/dam/fplgp/us/en/news/2025/fpl-ne...
18.8% Nuclear and 8.4% solar (more than double the national average!)
OUC on the other hand has less than 3% Nuclear (generated / purchased from FPLs plant on Hutchinson Islans!) and <6% solar, with a massive 24% still being generated by coal! (FPL demolished their last coal plant ~8 years ago in Indiantown, I watched it live!)
https://www.floridapsc.com/pscfiles/website-files/PDF/Utilit...
So while FPL is technically for profit and OUC is not... FPL is cheaper and greener than OUC.
I say this as a long time Florida resident who remembers when FPL truly sucked in many ways. They’ve, demonstrably, put in effort to make electricity greener and cheaper here in FL. (Even with all of their efforts against home solar).
Just how many natural disasters do Americans go through before realizing that?!
These disasters are rare though for any one person - a few happen every year, but it will be years between you personally seeing a disaster. That is why generators sell out when there is a storm: even if you have a generator odds are it is rusted and won't work. It is a waste of money to buy a generator before you need it.
This is one of the most condescendingly-wrong posts I've ever seen on this site and you should be embarassed for writing it. The beginning was just typical hn hubris that I probably wouldn't have responded to, but that last jab at the end in the context of an active and ongoing emergency that you clearly know nothing about is completely insensitive and gross.
Having traveled to those areas many times to assist with recovery, slept in trucks for weeks, and made many friends in those areas: It's day four without power and that is not abnormal. Bigger storms you can go weeks without power. Batteries aren't gonna cut it.
And gas generators have a whole mess of problems.
- Gas doesn't store well. Your stored gas is gonna go bad. That means when you find out a hurricane is coming to your area you can spend your time either protecting your house or wait 3-6 hours in line to hopefully get some gas for your generator before it runs out. Maybe they are rationing to 5-10 gallons.
- They might not work after sitting for years, even when properly maintained (one of my friends had two and neither could get running even with help). Hurricane areas are humid: generators rust. If you don't use gas engines the seals dryrot. If you leave them sitting with gas in them the ethanol (sugar!) Separates out and gums it up, breaking your generator. If you stop using your generator in the wrong way then you'll break it (you need to run it dry, using/wasting all the gas in the tank).
Even if you score gas and your generator works that brings us to the next problem:
The gas stations can't pump gas if they have no power themselves. They also can't be refilled if the big gas tankers can't reach them due to trees blocking roads. Main roads become passable quickly, side roads might not work for weeks. Cell phones might be out for weeks (and modern 5g micro-sites will take even longer to get fully rebuilt across a whole county). If your close-by station can't get gas you can't just call around to fine somewhere that does. You can't just drive around either. Single lane roads mean going anywhere takes forever and you are actively hindering recovery efforts. There are still stations in florida unable to pump gas due to shortages or power loss. So your couple of gas cans got you through a couple of days, what now?
And gas generators have moving parts. They are complicated. Another friend there had theirs die the day after the hurricane. Shit happens.
There is a reason prevalence of gas geberators in hurricane areas is less than 5% (I probably hear one running for every 50 houses, but most run them only intermittently) and it isn't because they're just dumb hicks who aren't as smart as mschuster91.
Lastly, you need to know how to use one. Every time there's a hurricane someone puts it in their garage and poisons themself and their family to death. Should you know better? Yes. But everyone doesnt.
Then there's all the other ways you suddenly need to spend energy to survive: you need to boil water, sometimes for weeks (while you don't have power), you need gas for your chainsaw to clear roads/trees so that power and water can be brought back. You need to drive to get supplies. Wasting gas that could be used to recover from the disaster isn't wise.
Back on topic: A stack of solar panels that could plug into the same outlet as a fridge would be a godsend for a lot of people (while also storing better than a generator and being more compact -- so more can be trucked in after a disaster.)
This is a nice grassroots technology that lets motivated individuals take action.
And since transmission cost is typically bundled with the energy cost, it means the final retail energy price has to go up to cover the transmission cost.
Utility companies are not incentivized to lower prices because it means less money for them. Do you remember when power companies told people to conserve power and then people successfully did this? And then they raised rates because they weren't making enough money? This happens in California ALL THE TIME. I've lived here 30 years in Silicon Valley and it's the biggest scam that no one talks about. It happens with electricity and water. With water its even more egregious because they told us to conserve water because of the "drought" but once the drought was over, they raised rates because people weren't using enough water. My connection fee to water is over $100/month without spending a drop of water. That's why I stopped conserving water and water my lawn every single day because it turns out that my water costs are only about 1/3 of the actual water bill costs so fuck it!
It's the same playbook over and over again, there's no incentive to lower rates at all because it's an easy way to make money over an entire population of tens of millions of people.
Now PG&E is fighting to charge solar panel owners $100+/month just for the privilege of being connected to the grid. That would make having solar panels even more expensive than not having solar panels which is utter hypocrisy but no one seems to care or point this out. It's a complete and utter scam.
EDIT: I forgot to mention last year the rates were $0.37-0.45 per kWh, until this year when they implemented a base fee of $25/month, so they lowered it to $0.33-0.45/kWh. Rates in Nevada are 1/4 of that.
2015: $0.17-0.33 per kWh
2020: $0.24-0.38 per kWh
so prices have more than doubled in 10 years. Fucking criminals.
The day after the system goes live, they'll probably announce flat rates for any time of day, just to f' with me. :(
I am a staunch DIY serial entrepreneur techie that has used my grey goo to build and sell a few companies and my time now is spent similar to yours although using a different application of physics. I too am motivated, just as you are, in my efforts to apply what I know to further reduce my energy costs which will not stop rising for quite some time.
You really made my day with this post and I hope we can find more folks like ourselves from your share because in time 'dogfooding' new ideas at home will lead to new applicable discoveries for all.
Stay Healthy!
Every system like yours works to flatten the prices, but it looks like a pretty big swing between peak and off peak pricing today, so it'll probably be a while before flat pricing again.
The more stable you think the future will be, the more you want to capture the efficiency of central power.
I'm not saying you're necessarily wrong, I just don't see society taking that measure until it's either 1) cheaper, or 2) the threat moves from being just a threat to reality.
Completely agree. But I'm already there. Large scale economic disruption has just started. For that to remain peaceful over the next few decades would be a miracle. So we should plan for disruption, for which energy decentralization is a keystone, and the technology to make it practical is here.
California has a 600 MW Virtual Power Plant composed of Tesla Powerwall batteries in 85k homes. Central control of distributed generation removes a lot of inefficiencies. Household excess is available to the whole system.
With fixed solar installs you're likely to find some kind of switch or labeled breaker to disconnect. The system is designed with a central "power in" that's (hopefully) obvious/proximate when you're standing in the breaker room.
These things could be injecting power anywhere, so you need to know they're there (which may be less apparent than roof/field panels) and go around and pull the plug(s). Relevant to electricians, firefighters, etc.
Your circuit breaker protects your circuits by putting all the load (eg your microwave) on one side, and your supply (mains power) on the other. If too much load is present, the circuit breaker trips.
However, plugin solar puts invisible supply on the load side, which your circuit breaker cannot see. Let's make an absurd example so you can see what the problem is, then scale it back.
Imagine someone buys 5 panels that can each supply 5amps. They plug them into outlets on a 40 amp circuit. They then proceed to run their toaster, microwave, vacuum, and hair dryer. They can draw 65 amps through the wires before the circuit breaker trips. (40 from mains, 25 from the panels)
Let's say they had a good electrician who installed 6AWG wiring on that circuit, which is rated for 50 amps. The circuit breaker used to trip at 40, so no problem. But now up to 65 can go across the wires and suddenly you are exceeding rating for wires.
Now you might say, "most of these are 3.5 watts, and they clearly say don't use more than one". But I say that's a "good intentions solution". We should make it mechanically impossible to do the wrong thing. Maybe these panels could try to communicate over the electrical wires, and if they detect a signal from another panel they should self limit. Maybe we need to rethink circuit panel design. But as it stands people will absolutely buy one of these, decide they love it, and then buy 4 more.
In the original example, RCD/circuit protection is regulated on the _property_ side, e.g UK has EICR for electrical install. Once its done for a property, its good until next inspection (in theory)
This moves the protection to the _appliance_ , which while it needs to meet certification, is much harder to police a consumer electronic device, than a physical unmovable premise.
I think these are great, but there will inevitably be devices that don't implement the spec correctly that still get sold to willful or unwillful consumers that result in danger to everyone.
Circuit breakers trip bidirectionally, so the circuit breaker itself would protect if too much current is drawn through to the mains panel.
How, precisely, would you get 65A through the wiring on this 40A circuit, if I drew 40A of consumption and had 25A of supply?
The 25A cancels out the 40A, so the upstream feed would only see 15A total. You do get 65A of total current drawn through the breaker panel, which is a concern, but the supply wiring would not see 65A. Subpanels (which, this would be a subpanel if it only had 40A capacity) are typically going to be just fine.
In the UK you typically make a ring circuit. In the US you make branching circuits.
In the US you get: Mains -> Breaker -> Outlet 1 -> Outlet 2 -> Outlet 3.
In the UK you get: Mains -> Breaker -> all outlets -> Breaker
In the US, assume I had 65A of load on outlet 3 -- I've plugged in too many things into a surge protector. Assume a bunch of solar panels are on outlet 1.
The the diagram looks like: Mains -40A-> Breaker -40A-> Outlet 1 -65A-> Outlet 2 -65A-> Outlet 3
Now, the breaker won't trip because only 40A are crossing the breaker. But 65A are on the wire between outlet 1 and 2 and between 2 and 3.
I think this is probably fine, since UK circuits are typically 20A. Apart from fault current (which would have to be line to line, since line to ground would trip the RCD), it's quite hard to end up with more than 20A of stuff plugged into regular sockets unless you're overinvested in portable heaters. All the big stuff - cookers, heat pumps, showers - is on separate breakers from the sockets.
They’d also probably depend on a power signal to frequency match.