comment 1mo ago · link · parent

> There's always going to be somebody on site who can control things locally.

No, there is not always someone onsite with the experience and knowledge to monitor and change the system. Grocery stores do not have staff refrigeration techs onsite, they contract that out.

comment 1mo ago · link · parent

I understand you’re being sarcastic, but yes, eventually technology gets better so a manufacturer refreshes their product line. This is extremely common in many industries.

comment 1mo ago · link · parent

They aren’t fridges, it’s a grocery store. You have obviously been in one, there are cases with a dozen doors that all open to the same cold case.

There is a ton of refrigerant piping, multiple condensing units, multiple evaporators, relays, and sensors connected to a controller that automates the refrigeration system. Not standalone refrigerators.

I shouldn’t need to list the benefits of remotely monitoring a system that can cause tens or hundreds of thousands of dollars if it fails.

comment 1mo ago · link · parent

Grocery stores do not use standalone refrigerators, I’m not sure why I have to keep repeating this fact when every single person has been in a grocery store and seen refrigerated cases that have a dozen or more doors.

They use cold cases and have rooftop or outdoor condensing units and evaporators inside of the cold cases/freezers/etc. There’s refrigerant piping running all over the place and there’s a bunch of sensors and relays that are automated to manage the refrigeration system.

My assumption is the Danfoss control system they’re using is EOL, it’s the grocer’s responsibility to upgrade their automation equipment if it’s unsupported.

comment 1mo ago · link · parent

Have you ever been to a grocery store?

These aren’t consumer refrigerators, it’s a collection of large cold rooms and cases with a bunch of refrigerant tubing and multiple condensers, evaporators, and sensors. It’s a bit more complex than a single home refrigerator.

comment 1mo ago · link · parent

> there is zero reason to put a refrigerator's cooling system online.

There are plenty of good reasons to do that. It’s not a consumer refrigerator, it’s a collection of evaporators and condensers and sensors that are controlled by an automation system. Remote monitoring can alert operators to problems so they can be fixed before the food spoils.

Authentication is hard.

comment 1mo ago · link · parent

You don’t need a FAANG salary, that just makes it easier. My net worth is nearing $1M after saving for 8 years, making less than $100,000 a year. If I exclude the ESOP equity I have, it’s still over $500,000 and that’s just maxing out 401K and Roth each year for 8 years with the market return.

comment 1mo ago · link · parent

Nobody understands the mechanism behind general anesthesia, yet there’s a medical speciality dedicated to practicing it and it’s done every single day for a wide variety of procedures. We have figured out how to use general anesthesia in a relatively safe way, but nobody understands why it works.

comment 1mo ago · link · parent

> Before injecting this cocktail into your bloodstream, would you want to know that there is at least one human cancer expert who understands the mechanism behind this cure?

No, and if that was the burden of proof required for medical treatment, every surgery would be done without general anesthesia, because we have no idea how it works.

I would imagine Terence Tao would opt for general anesthesia if he was going to have surgery where it is typically used, so the analogy is obviously flawed.

comment 1mo ago · link · parent

They meant HDPE but assumed it was PEX, which it isn’t. PEX is cross linked polyethylene and used for mostly indoor piping, and HDPE is high density polyethylene. Common mistake.

HDPE is used extensively in all underground utilities, including but not limited to water, sewer, gas, electric, fiber.

comment 1mo ago · link · parent

It has always been might makes right, are you under the impression it wasn’t that way at some point? I’m not endorsing the actions of the current administration, simply stating how global geopolitics works. There’s no such thing as a supranational organization that can force a nuclear power to do anything of consequence.

The only people that get prosecuted by the ICC are people that lose wars (no winner has ever been prosecuted) and are also from nations that do not have nuclear weapons / nuclear protection.

comment 1mo ago · link · parent

They do grow sugarcane in the south, it gets made into sugar. I’d guess that there’s orders of magnitude more land suitable for farming corn than there is for farming sugarcane, given the needs of sugarcane.

comment 1mo ago · link · parent

Easy, (e) is fraud. The rest are legal. You can choose to not do something, advertising is analogous to convincing and advertising is legal.

Collecting money from a platform by making bots play songs you created is fraud.

Making bots listen to a song without any financial incentive is not fraud.

comment 1mo ago · link · parent

Yes, I expect restaurant chain prices to vary based on the cost of renting the real estate and local labor costs (or a captive audience like an airport terminal). Per location pricing is fine with me, I dislike the idea of targeted pricing per customer.

Allowing people to trade their personal data for discounts like McDonalds does now is also fine by me, I just pay the full price and don’t use the app if I stop there.

comment 1mo ago · link · parent

That makes sense, the boreal taiga forest of Eurasia and North America covers over 10% of earth’s land.

comment 1mo ago · link · parent

If I were to tackle this project, I’d use an ESP32 and a relay with 120V contacts. That way you can use a GFCI receptacle and be code compliant if your darkroom is in a basement or the enlarger receptacle is near your darkroom sink.

comment 1mo ago · link · parent

I hope you had a speech you gave to the drywall crew on each new project, something like:

“This is my hammer, it would do you well to remember it. If you don’t bury my boxes, you will not see my hammer again. If you bury my boxes, I guarantee you will see and feel my hammer. The decision is yours.”

comment 1mo ago · link · parent

I assume they sent the email at least one minute prior to publishing the article when the sentence is phrased like that, it doesn’t really mean anything other than “We have asked them a question and have yet to receive any reply”. The waiting period could actually be a single minute and still be truthful.

comment 1mo ago · link · parent

Most drywall is installed in commercial buildings with drop ceilings, not houses. Tenant spaces usually get rebuilt every 10 years.

It’s dead ass simple when 95% of the walls extend beyond the grid, there’s very little hardlid ceiling in most commercial spaces.

Professional drywallers have panel hoists that can lift drywall 12’ tall.

comment 1mo ago · link · parent

Not necessarily, a non-SCUBA trained electrician may choose to bid the job with the condition that the customer drains the pool before the electrician starts their work.

I have some electricians that work for me with rope access training and certifications, sometimes we bid a job using rope access instead of a hydraulic lift if it’s cheaper to do it that way. It all depends on the project and your competition.

comment 1mo ago · link · parent

They’re engineered like this because 99.9% of tape storage media is sold to corporations who store their backups in climate controlled buildings with backup generators.

comment 1mo ago · link · parent

Easy, it’s cheaper to pay the electrician to use his SCUBA gear than it is to drain and fill a pool with water.

comment 1mo ago · link · parent

Drywallers don’t understand anything except “it’s my turn to hang gypsum board.” It will be one of the first trades that is completely automated.

Mechanical, electrical, and plumbing contractors need to understand the most since their work goes all over the building and they’re on the project from start to finish.

Drywallers just come in and put up gypsum once walls have been framed and MEP has been roughed in, and then they leave.

Tapers and mudders command my respect, that’ a difficult trade to perfect. Holding up 4’ x 8’ sheets of gypsum and screwing it to studs might be hard work but it’s dead ass simple.

comment 1mo ago · link · parent

> Residential has to deal with individual home owners, house flippers, renovation GCs and weird change orders

In other words, the customers are awful. I sell and run commercial and industrial electrical work, I’d rather go do something completely different as a career than deal with homeowners, flippers, and residential GCs. The work itself has zero challenge and requires almost no thinking, it’s not hard to pull and fish romex through finished walls.

comment 1mo ago · link · parent

What do you mean? I’d much rather pay $30 for a separate LED driver and LED module that will last x0,000 hours and comes with a five year warranty instead of crappy LED lamps that last a few thousand hours.

Cooper makes the HALO RL series LED can retrofit modules that can be had for $30 with adjustable color temp and dimming capable, with a five-year warranty.

comment 1mo ago · link · parent

I always see people complaining about failing LED lamps. It’s almost always because people are using lamps rated for open fixtures in enclosed fixtures. If it’s not a table lamp or standing lamp, it’s likely an enclosed fixture. A recessed can with an open bottom is considered an enclosed fixture, and so is an open-bottom chandelier globe.

I suggest only buying enclosed rated fixture lamps because they put out less heat and will last longer in an open or enclosed fixture.