comment 2mo ago · link · parent

Yes, a solid-state motor starter uses semiconductors (thyristors) to switch the line voltage power instead of using (an) electromagnetic contactor(s): https://www.eaton.com/content/dam/eaton/products/industrialc...

comment 2mo ago · link · parent

There are no solid state electronics or semiconductors in basic AC transformers, it’s an iron core with aluminum windings coated with enamel and wrapped in paper with a bit of wire and some taps and lugs for terminations.

comment 2mo ago · link · parent

I suppose they manufacture distribution or transmission transformers, I buy a lot of dry-type transformers and have never seen a Hitachi one, it’s almost always a Siemens/ABB/Square D/Eaton/Hammond.

comment 2mo ago · link · parent

You don’t even need to read it, the title of the article implies its satirical nature given it is paraphrasing the subtitle from the film Dr. Strangelove.

comment 2mo ago · link · parent

Quite an apropos username for a post praising BoC :)

comment 2mo ago · link · parent

Assuming you have a 200A service, you don’t need to replace your panel. You can remove two single pole breakers or one two pole breaker, install a 100A two pole breaker in the empty space, buy some 3/#1 copper SER cable (two hots and one neutral for 240/120V) and use it to feed a $125 100A load center without a main breaker.

You need to use #1 copper for a 100A subpanel, you can use 3/#2 aluminum cable for a 100A service entrance but there’s an exception that allows using wire rated at 83% of its ampacity for a service entrance conductor which does not apply for subpanels.

Refeed the two removed breakers out of the load center and add a 60A two pole breaker to feed the EV charger, if it’s a cord and plug charger that you plug into a NEMA 14-50R you’ll need a GFCI breaker, if it’s hardwired you don’t need a GFCI breaker.

The material can be purchased for less than $500 for this project, if you have to hire out the labor it’ll be considerably more expensive, I’d estimate one day for an electrician or around $1200-1800 depending on where you live.

comment 2mo ago · link · parent

Please provide proof for the billions of dollars claim, thank you.

comment 2mo ago · link · parent

A judge ruled it was OK to scan books and save the scanned copy if you shred the physical book afterwards.

comment 2mo ago · link · parent

Feel free to buy books by the ton and preserve them yourself. The simple fact they’re being sold by weight implies they’re not rare or unique.

comment 2mo ago · link · parent

If you’re lazy and don’t mind dealing with a few ads, search yandex for ‘[content name] free stream’ and use one of the many pirate stream sites that show up in the results. Adblocker highly recommended.

I have access to a well-seeded 20+ year old private tracker but usually use the above method to stream content for free these days.

comment 2mo ago · link · parent

> I remain baffled when people buy a 7 year old used V6 Traverse, a vehicle extremely well known for catastrophic engine failure

I’m puzzled as well, buying a car that depreciates 60-70% in 7 years seems like a horrible idea, you could spend roughly the same on a Toyota Highlander or Honda Pilot and only face 30-40% depreciation after 7 years. This information is freely available if you google “[vehicle model] depreciation curve”.

Nissan (and Stellantis, Mitsubishi) decided to stop making better cars and focus almost exclusively on subprime lending, the rest of the story tells itself once you have that information.

comment 2mo ago · link · parent

Food delivery services offer convenience for a price. If I hire a courier service to bring some materials and tools to one of my electricians, it’ll cost me a minimum of $50.

I can pay a bit extra for food and $10 in tips and fees to have it delivered to me instead of spending half an hour driving to go get it myself. I know what I’m paying for and value the service they provide.

comment 2mo ago · link · parent

There are a couple of metro areas that escaped this problem by having regional government, Mpls/St Paul, MN and Portland, OR.

Minnesota has the Metropolitan Council which derives its power from state statute and can supersede the decisions of local governments. The same people that bitch about ‘my tax dollars’ complain about the Met Council but I feel it provides a cohesive regional planing organization and they provide water, sewer, transportation, and regional parks. https://en.wikipedia.org/wiki/Metropolitan_Council_(Minnesot...

Portland, Oregon has a similar organization called Metro that I am not familiar with, other than it is similar to the Metropolitan Council. https://en.wikipedia.org/wiki/Metro_(Oregon_regional_governm...

comment 2mo ago · link · parent

Ah I see what you’re referring to.

I was taught that the safe way to keep using the old pre-8000 series wire is to use the specific listed fittings for this purpose (WAGO 221 series nuts are fit for purpose) with contact paste and a copper pigtail that connects to the device.

comment 2mo ago · link · parent

Oh yeah, I forgot about the built in door switch, good call XD

comment 2mo ago · link · parent

The word “socialist” was strongly associated with the USSR in the Cold War era United States. Anyone advocating for socialism was dismissed as a red pinko commie spy.

See Joseph McCarthy, HUAC, Hollywood blacklists, J. Edgar Hoover’s COINTELPRO and other domestic surveillance programs for a small slice of anti-communist efforts in the Cold War US.

comment 2mo ago · link · parent

I’d just throw an analog min/max thermometer in there and investigate if the max temp goes above 40F, sounds a lot easier than adding a temp probe and door switch to a residential refrigerator.

comment 2mo ago · link · parent

A bimetallic strip thermostat with a ‘cool/off/heat’ mode switch and ‘on/off/auto’ for fan control is all anyone actually needs with a fixed speed compressor and generic furnace with a fixed speed fan.

If you have a fancy modulating furnace and variable speed compressor or a variable speed heat pump, a thermostat that uses a PID would work better.

comment 2mo ago · link · parent

Aluminum wire is completely safe these days. Wiring devices and breakers have accepted both Cu/Al wire for the last 50 years.

There was an issue with aluminum wire and terminations, the wiring devices and breakers used for copper only wire didn’t work with aluminum (wrong coefficient of expansion of the metal where the terminations were made) and caused arcing and fires. Once the termination points were made out of an alloy that worked with both Cu/Al, it’s been safe to use.

comment 2mo ago · link · parent

Oh awesome! I’m glad there are others in the industry around here :)

I’d like to learn more about PLCs and SCADA, but that scope of work usually falls on another contractor, we mostly provide installation for BAS systems that control HVAC and chilled/hot water plants.

I do some water treatment plant projects and there’s a local contractor that handles the PLC and SCADA stuff.

comment 2mo ago · link · parent

I imagine Oracle lawyers to be identical to the Cylons pointing guns at President Gaius Baltar and forcing him to sign death warrants on New Caprica.

https://youtu.be/2_nUztwPiEY

comment 2mo ago · link · parent

A residential electrician would be completely lost on a data center site. Commercial electricians travel around to the various data center projects. Most of the trades are similar.

comment 2mo ago · link · parent

> You don't get, for example, datacentre electricians rocking up pretenting they can install network cable to spec and running away having (if you are lucky) only done a continuity test on the cable they just installed.

I frequently have my electricians pull and terminate network cable if it’s only one or a few (daisy-chained VAV controllers or a network drop for a BAS panel), if the customer needs a formal TIA-568 test then I’ll sub that out. My electricians are already pulling and terminating building automation cable, CAT 6 isn’t gonna stop em :)

comment 2mo ago · link · parent

Indeed, tracer wire is usually bonded to a (sacrificial) magnesium anode, but it’s a crapshoot whether the tracer wire is still intact.

I sometimes hire directional boring and excavation contractors and if there’s any doubt as to where an electrical conduit or natural gas pipe is, I opt for the hydrovac truck to minimize risk.