1,688 karma · joined Feb 4, 2016 (10y ago) · 257 submissions
1.
Shibboleth IDP and SP: Forthcoming security updates(shibboleth.net ↗)
1 points · by terom · 16h ago · discuss
comment 2w ago · link · parent
> How your data is used
> This data is used to create personal insights about you, your relationships, and the people and things in your world. For example, depending on your settings, your Google Photos data is used to infer your interests, relationships to people in your photos, and where you've been, including by associating your face with corresponding location data and timestamps. This data is also used to do things for you, like look up your info or add items to your grocery list, and to improve Google services, including training generative AI.
https://support.google.com/gemini/answer/16836988#common_que...
> How your Connected Apps data is used to improve Google services
> Gemini Apps activity, which includes data from apps you connect, is used to improve Google services for everyone, including by training generative AI models, if your Keep Activity setting is on.
> When connected to Gemini, a subset of Connected Apps data processed by Gemini is reviewed by human reviewers (including trained service providers) to debug our services, help keep them safe, and improve them.
> Human reviewers improve Google services, including generative AI. Reviewers assess if Gemini responses were low-quality, inaccurate, or harmful. They also suggest better responses. We use their suggestions to help our models respond better in the future.
> Important: Please don't connect your apps to Gemini Apps if they contain confidential information that you wouldn’t want a reviewer to see.
comment 3w ago · link · parent
Given, without any network level DHCP guard configuration, you could likely also send your own DHCPOFFER and just tell it to PXE-boot your own image :) I suppose for some trusted-boot threat scenarios code execution at the UEFI level is a bigger issue. No idea how modern UEFI PXE-boot deals with signed images.
comment 7mo ago · link · parent
comment 11mo ago · link · parent
Oldschool maven type jobs where you type shell script into a `<textarea>`? Yeah, let's not talk about those, but we don't have a single one left anymore.
comment 11mo ago · link · parent
downdetectorsdowndetectorsdowndetector.com and downdetectorsdowndetectorsdowndetectorsdowndetector.com seem like they might be legit. One has the results in the HTML, the other fetches some JSON from a backend (`status4.php`).
comment 1y ago · link · parent
> On the Boeing 767, the control surfaces are so large that the pilots cannot move them with muscle power alone. Instead, hydraulic systems are used to multiply the forces applied by the pilots. Since the engines supply power for the hydraulic systems, in the case of a complete power outage, the aircraft was designed with a ram air turbine that swings out from a compartment located beneath the bottom of the 767,[10] and drives a hydraulic pump to supply power to hydraulic systems.
> As the aircraft slowed on approach to landing, the reduced power generated by the ram air turbine rendered the aircraft increasingly difficult to control.[16]
> The forward slip disrupted airflow past the ram air turbine, which decreased the hydraulic power available; the pilots were surprised to find the aircraft slow to respond when straightening after the forward slip.
comment 1y ago · link · parent
> Cloudflare’s critical Workers KV service went offline due to an outage of a 3rd party service that is a key dependency. As a result, certain Cloudflare products that rely on KV service to store and disseminate information are unavailable [...]
Surprising, but not entirely unplausible for a GCP outage to spread to CF.
comment 1y ago · link · parent
Looks like there is a change [2] coming to the `management.endpoint.heapdump.access` default value that would make this harder to expose by accident.
Let's look for `env` next...
[1] https://docs.spring.io/spring-boot/reference/actuator/endpoi...
[2] https://github.com/spring-projects/spring-boot/pull/45624
comment 1y ago · link · parent
Unfortunately that's where it seems to end... I'm not that familiar with QUIC and HTTP/2, but I think the closest it gets is that the GitHub repo exists and has a `class QuicConnection` [3]. Beyond that, the QUIC protocol layer doesn't have any concept of exchanging stream priorities [4] and HTTP/2 priorities are something the client sends, not the server? The PoC also mentions HTTP/3 and PRIORITY_UPDATE frames, but those are from the newer RFC 9218 [5] and lack the stream dependencies used in HTTP/2 PRIORITY frames.
I should learn more about HTTP/3!
[1] https://blog.cloudflare.com/adopting-a-new-approach-to-http-...
[2] https://www.imperva.com/docs/imperva_hii_http2.pdf
[3] https://github.com/aiortc/aioquic/blob/218f940467cf25d364890...
[4] https://datatracker.ietf.org/doc/html/rfc9000#name-stream-pr...
[5] https://www.rfc-editor.org/rfc/rfc9218.html#name-the-priorit...
comment 1y ago · link · parent
[1] https://transparency.entsoe.eu/load-domain/r2/totalLoadR2/sh...
comment 1y ago · link · parent
There seems to be some kind of recurrent daily pattern where the French - Spanish interconnect switches from Spain -> France imports to France -> Spain exports at around that time, and then back again in the late afternoon.
comment 1y ago · link · parent
There's a map at [2]
> The Spanish electricity system is currently connected to the systems of France, Portugal, Andorra and Morocco. The exchange capacity of this interconnection is around 3 GW, which represents a low level of interconnection for the peninsula. The international interconnection level is calculated by comparing the electricity exchange capacity with other countries with the generation capacity or installed power.
[1] https://www.ree.es/en/ecological-transition/electricity-inte...
comment 1y ago · link · parent
But the same AUP for the services is now explicitly referenced in the TOS for the browser. How are you supposed to read it - the AUP only applies to your use of the browser to access the services? Isn't that already implicit if you're using the services? Surely it can't be attempting to apply the services AUP to any non-service use of the browser?
Very confusing, it seems badly written to me.
Same thing with the "Some Services in Firefox Require a Mozilla Account" and then the "Termination" with a notification to the (optional) account. Somewhat disconcerting.
[1] Mozilla can suspend or end anyone’s access to Firefox at any time for any reason, including if Mozilla decides not to offer Firefox anymore. If we decide to suspend or end your access, we will try to notify you at the email address associated with your account or the next time you attempt to access your account.
[1] https://www.mozilla.org/en-US/about/legal/terms/firefox/#moz...
comment 1y ago · link · parent
What's with the mixup of their browser and services policies?
[1] Your use of Firefox must follow Mozilla’s Acceptable Use Policy, and you agree that you will not use Firefox to infringe anyone’s rights or violate any applicable laws or regulations.
[2] You may not use any of Mozilla’s services to:
* Upload, download, transmit, display, or grant access to content that includes graphic depictions of sexuality or violence,
[1] https://www.mozilla.org/en-US/about/legal/terms/firefox/#you... [2] https://www.mozilla.org/en-US/about/legal/acceptable-use/
comment 1y ago · link · parent
I do hope that dealing with all of the underlying issues around revocation etc makes the time and effort spent useful, and the Web PKI doesn't just mire itself in squabbling that blocks progress on actually meaningful issues.
comment 2y ago · link · parent
https://www.vde.com/de/fnn/themen/tar/tar-niederspannung/erz...
https://tukes.fi/-/ala-kayta-pistorasiaan-kytkettavaa-aurink... Finnish national authority says: NO
comment 2y ago · link · parent
Rotating the keys would make some sense, but just swapping the cert for a new one issued against the same keys doesn't. It's the easiest way to fulfill those requirements, because you don't need to synchronize the metadata updates, the signatures are always valid with both the old and new cert.
comment 2y ago · link · parent
> 2024-01-22 > 08:25 The error message “ERROR: basicConstraints MAY appear in the certificate, and when it is included MUST be marked as critical “ in crt.sh was found in our weekly checks
> 2024-02-05 > 13:00 Videoconference with the management of the Trust Center with the decision, to revoke all certificates that have not yet been revoked the next day > 13:25 Information to customers about the final revocation of all certificates the next day
> 2024-06-02 > 15:41 All affected certificates are replaced and revoked.
Given the comment was posted 2024-02-09, the last date is probably a typo of 2024-02-06, aka within 16 days.
comment 2y ago · link · parent
comment 2y ago · link · parent
AFAIK the broken crowdstrike channel update happened at 2024-07-19 06:05 UTC and was "fixed" (rolled back) at 06:47 UTC, but I don't have a proper source for that timeline?
EDIT: https://azure.status.microsoft/en-gb/status claims 2024-07-18 19:00 UTC as the approximate start of impact for the crowdstrike update. It would be nice to find a proper source for the start and mitigation timelines...
EDIT: reddit threads reporting symptoms start at approx 2024-07-19 05:00 UTC. That would mean the crowdstrike impact started soon after the azure recovery.
---
What happened?
Between 21:56 UTC on 18 July 2024 and 12:15 UTC on 19 July 2024, customers may have experienced issues with multiple Azure services in the Central US region including failures with service management operations and connectivity or availability of services. A storage incident impacted the availability of Virtual Machines which may have also restarted unexpectedly. Services with dependencies on the impacted virtual machines and storage resources would have experienced impact.
What do we know so far?
We determined that a backend cluster management workflow deployed a configuration change causing backend access to be blocked between a subset of Azure Storage clusters and compute resources in the Central US region. This resulted in the compute resources automatically restarting when connectivity was lost to virtual disks hosted on impacted storage resources.
How did we respond?
21:56 UTC on 18 July 2024 – Customer impact began
22:13 UTC on 18 July 2024 – Storage team started investigating
22:41 UTC on 18 July 2024 – Additional Teams engaged to assist investigations
23:27 UTC on 18 July 2024 – All deployments in Central US stopped
23:35 UTC on 18 July 2024 – All deployments paused for all regions
00:45 UTC on 18 July 2024 – A configuration change as the underlying cause was confirmed
01:10 UTC on 19 July 2024 – Mitigation started
01:30 UTC on 19 July 2024 – Customers started seeing signs of recovery
02:51 UTC on 19 July 2024 – 99% of all impacted compute resources recovered
03:23 UTC on 19 July 2024 – All Azure Storage clusters confirmed recovery
03:41 UTC on 19 July 2024 – Mitigation confirmed for compute resources
Between 03:41 and 12:15 UTC on 19 July 2024 – Services which were impacted by this outage recovered progressively and engineers from the respective teams intervened where further manual recovery was needed. Following an extended monitoring period, we determined that impacted services had returned to their expected availability levels.
comment 2y ago · link · parent
> Update as of 10:30 UTC on 19 July 2024: We have received reports of successful recovery from some customers attempting multiple Virtual Machine restart operations on affected Virtual Machines.
> We've received feedback from customers that several reboots (as many as 15 have been reported) may be required, but overall feedback is that reboots are an effective troubleshooting step at this stage.
comment 2y ago · link · parent